Lyons Hall Fire Safety System Information, 2014
Building Name: Lyons Hall
Address: 401 Euclid Avenue
Building Size: 3 floors plus basement, 2 exits
Building Capacity: 38
Fire Protection Systems
Sprinkler System: Wet system throughout building including 100% of student rooms; 2 pre-action dry systems cover the electrical vault and the elevator mechanical room.
Fire Pump: 1,000 GPM Electric Flow Meter
Fire Alarm Control Panel: FCI
Addressable Pull Stations: 8
Sprinkler Supervisory: 1
Photo-Electric Smoke Detectors: 26
Water Flow Switches: 2
Heat Detectors: 2
Roof Hatches: 2
Duct Detectors: 0
Fire Shutters/Louvers: 0
Alarm: Bells 2/ Visual, 5; Strobes only, 2
Beam Detectors: 0
Fire Extinguishers: 5
Alarm System Type: Campus Tie
Ansul Systems: 0
Inspections Requirements: NFPA 72 (1 thru 7)
Inspection, Testing, and Maintenance
Evacuation Drills: 2/10/2014, 3/18/2014, 9/23/2014, 11/4/2014
Smoke Detection Certification: 5/19/2014
New York State Office of Fire Prevention and Control Inspection: 10/26/2014
Date | Cause |
---|---|
10/21/2014 | Accidental |
Marion Hall Fire Safety System Information, 2014
Building Name: Marion Hall
Address: 303 Waverly Avenue
Building Size: 3 floors plus basement, 6 exits
Building Capacity: 149
Fire Protection Systems
Sprinkler System: Wet system throughout building including 100% of student rooms; 2 pre-action dry systems cover the electrical vault and the elevator mechanical room.
Fire Pump: 1,000 GPM Electric Flow Meter
Fire Alarm Control Panel: EST-3
Addressable Pull Stations: 11
Sprinkler Supervisory: 8
Photo-Electric Smoke Detectors: 48
Water Flow Switches: 6
Heat Detectors: 4
Roof Hatches: 0
Duct Detectors: 197
Fire Shutters/Louvers: 0
Alarm: Horns w/ Visual, 14
Beam Detectors: 1
Fire Extinguishers: 15
Alarm System Type: Campus Tie
Ansul Systems: 0
Inspections Requirements: NFPA 72 (1 thru 7)
Inspection, Testing, and Maintenance
Evacuation Drills: 2/21/2014, 3/24/2014, 10/2/2014, 11/4/2014
Smoke Detection Certification: 5/12/2014
New York State Office of Fire Prevention and Control Inspection: 12/3/2014
Date | Cause |
---|---|
12/17/2014 | Unknown |
Park Point Fire Safety Systems Information, 2014
Building Name: Park Point
Address: 417 Comstock Avenue
Building Size: 5 floors, 4 exits
Building Capacity: 66 apartments
Fire Protection Systems
Sprinkler System: Wet system throughout building including 100% of student rooms.
Fire Pump: Yes
Fire Alarm Control Panel: Monitored 24/7
Addressable Pull Stations: 12
Sprinkler Supervisory: 1
Photo-Electric Smoke Detectors: 284
Water Flow Switches: 4
Heat Detectors: 3
Roof Hatches: 0
Duct Detectors: 23
Alarm System Type: Central Office
Ansul Systems: 0